Call For Best Price 1-888-484-0864

Hayward Pool Heater Exhaust Gas Temperature Limit | FDXLEGL1930

Hayward Products SKU: FDXLEGL1930

Hayward Pool Heater Exhaust Gas Temperature Limit | FDXLEGL1930

Hayward Products SKU: FDXLEGL1930
  • In stock, ready to ship
  • Inventory on the way
$25.75 Regular price $32.99
Instant Savings: $7.24Sale price $25.75
/
🚚 Shipping notice loading...
Questions about returns? View our return policy.
Free US Shipping - Shipping Policy

Hayward FDXLEGL1930 Exhaust Gas Temperature Limit (One-Use) — Universal H-Series / FD / H-Series 135K / Universal HC

The Hayward FDXLEGL1930 is an OEM exhaust gas temperature limit safety device used on select Hayward pool heaters. This is a one-use (non-resettable) limit that helps protect the heater by shutting it down if exhaust gas temperatures exceed safe operating levels. It’s a critical safety component for preventing damage from overheating, airflow restriction, or combustion issues.

Fits / Compatibility

  • Hayward Universal H-Series heater applications (model/revision dependent)
  • Hayward Universal H-Series Low NOx FD heater applications (model/revision dependent)
  • Hayward H-Series 135,000 BTU induced draft / above-ground heaters such as H135ID and ABG135
  • Hayward Universal HC heaters including HDF275 and HDF400

Fit tip: Heater parts can vary by model and revision. Confirm your heater model from the data plate and verify FDXLEGL1930 on the correct parts diagram before ordering.

What It Fixes

  • Heater shutdown or lockout due to a tripped/failed exhaust temperature limit
  • Safety circuit open condition traced to a blown one-time exhaust limit device
  • Preventive replacement during combustion/venting service when the limit has been triggered

Common Causes of an Exhaust Limit Trip (Address Before Restarting)

  • Blocked or restricted exhaust/venting
  • Restricted air intake, debris in blower area, or poor combustion air supply
  • Exchanger/combustion chamber issues or soot buildup
  • Incorrect gas supply/combustion setup or other combustion-related faults

What’s Included

  • (1) FDXLEGL1930 one-use exhaust gas temperature limit

Specs (Quick Reference)

  • Part Number: FDXLEGL1930
  • Part Type: Heater Parts
  • Safety Type: One-use (non-resettable) exhaust gas limit
  • Pool Type: In-Ground
  • Warranty: 1-Year (Parts Only)

Installation Notes

  • Turn off power and gas to the heater before service and allow the unit to cool.
  • This is a safety device; if it has tripped, diagnose and correct the underlying cause before operating the heater again.
  • Installation and combustion/venting diagnosis should be performed by a qualified technician.

Related Products


Maintenance Tips

  • Keep the heater’s air intake and exhaust areas clear of leaves, insects, and debris to maintain proper airflow.
  • If the heater shows signs of soot or strong exhaust odor, stop use and have combustion inspected.
  • Maintain proper water flow and balanced water chemistry to reduce internal stress on the heater.
  • Address any safety shutdowns promptly—repeated cycling without fixing root causes can lead to larger failures.
Questions about returns? View our return policy.

Hours Of Operation:

Monday - Friday: 7:00 am to 5:00 pm Phoenix Time

Saturday: 8:00 am to 2:00 pm

Sunday: Closed

  • We do not ship on Saturday or Sunday.
  • Orders totaling more than $300 will require signature confirmation upon delivery.
  • We process and prepare orders for shipment within 1 business day. Please note that many other pool supply retailers require 3–5 days of handling time before shipping.
  • Orders placed after 1:00 pm Phoenix Time may not be eligible for same-day shipment.
  • Expedited shipping options are available at checkout.

Return Policy:

  • Products that are received damaged will receive a refund in store credit.
  • Most products are eligible for return within 30 days of receipt, except where noted below.
  • To initiate a return, please complete an RMA form prior to sending your item back.
  • Original shipping costs are non-refundable and will be deducted from the return credit.
  • Items returned missing accessories or original packaging, or that are not in the same condition as received, may be subject to a restocking fee of up to 100% depending on the condition of the item upon return.
  • Some returns will be charged an automatic 15% restocking fee.
  • We are unable to issue refunds for items that have been damaged or rendered inoperable due to installer error.
  • Please complete the return form to receive your RMA number and return shipping label.
  • Chemical products are not eligible for return under any circumstances.
  • The Pentair Colorsync 618031 is not eligible for return.
  • Pool cleaners are not eligible for return.
  • Opened seals and o-rings are not eligible for return.
  • Capacitors are not eligible for return.
  • Plastic popup tools are not eligible for return.
  • Automation components and circuit boards are not eligible for return.
  • If a light is returned due to a reported malfunction and is found to be fully operational upon testing, return shipping costs and a restocking fee will be deducted from the refund.
  • Orders refused at the time of delivery will be subject to the original shipping costs being deducted from the refund.