Hayward FDXLBWR1930 – Combustion Blower Kit for Universal H-Series Heaters

Product Overview

The Hayward FDXLBWR1930 is a complete factory replacement combustion blower kit designed for use with the Universal H-Series low-NOx pool and spa heaters. It provides the necessary blower hardware to maintain proper air-flow and combustion operation in the heater unit.

Key Features

  • OEM kit designed for Hayward Universal H-Series heaters (Natural Gas or Propane, low NOx) including models such as H150FDN/FD 150, H200FDN/FD 200, H250FDN/FD 250, H300FDN/FD 300, H350FDN/FD 350, H400FDN/FD 400.
  • Reliable blower assembly ensures efficient combustion air supply and stable heater operation.
  • Full replacement kit—includes blower motor, fan assembly, mounting hardware and wiring connections as required.
  • Backed by equipment-manufacturer compatibility to keep heater running safely and in code compliance.

Technical Specifications

  • Part Number: FDXLBWR1930
  • Application: Combustion blower kit for Universal H-Series pool/spa heaters
  • Weight: ~6.5 lb (shipping weight) and packaging size ~12″ × 12″ × 16″ per standard kit dimensions.
  • Warranty: 1 year parts only (for standard OEM replacement) when installed properly.

Compatibility & Fitment

This kit is intended for the Universal H-Series low-NOx pool and spa heater models manufactured by Hayward. Before purchasing, verify that your heater’s model number falls under the H-Series (for example H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP) and that the original blower kit part matches this replacement. Installing the correct blower helps maintain proper combustion, reliable heater start-up and safe operation.

Installation Instructions

  • Turn off all power to the heater and shut off the gas supply line before servicing.
  • Allow the heater to cool and relieve any pressure or gas residuals per manufacturer service instructions.
  • Remove the old blower motor assembly and mounting plate; disconnect wiring and controls carefully, noting original orientation.
  • Install the new blower kit: mount the fan/motor assembly, secure hardware, reconnect wiring, and verify proper alignment and clearance.
  • Restore gas and power supplies, then perform a test ignition cycle; monitor for correct blower operation, combustion sequence and absence of error/fault codes.

Troubleshooting & Maintenance Tips

  • Blower fails to start: Check power supply, motor wiring, fuse or breaker, and ensure the blower connector is securely attached.
  • Excessive noise or vibration: Confirm the fan is mounted correctly, balanced, and no foreign objects obstructing blower wheel.
  • Heater faults out or doesn’t maintain flame: The blower may be under-performing; verify correct blower kit installation, airflow path and no intake or exhaust blockages.

Maintenance Tip

Inspect the blower assembly annually during heater service. Clean any dust or debris build-up, check mounting bolts for tightness, and ensure the blower motor cooling vents are clear of obstruction. Replacing worn blower kits like the FDXLBWR1930 proactively can help avoid heater downtime and premature component failure.

Hours Of Operation: 

Monday - Friday: 8:00 am to 4:00 pm Phoenix Time

Saturday and Sunday: Closed

  • Orders costing more than  $300 WILL be required to have signature confirmation upon delivery.
  • Handling time is typically only 1 day.   
  • Any item ordered after 1pm Phoenix time, may not ship same-day.
  • Call us if you require expedited shipping and we can give you quotes based on your needs.

Return Policy:

  • All products, except as noted below, are eligible for return up to 30 days after receipt of item.
  • For returns, an RMA form must be filled out HERE or customers can call for additional help.
  • Shipping costs will be deducted from all returned items.
  • Any item that is missing accessories, original packaging, or is not returned in the same condition that it was received in, may be subject to a re-stocking fee up to 100% based on the condition we receive it in. 
  • Items broken, damaged, or inoperable due to installer error will not be refunded.
  • Fill out the return form or give us a call to obtain an RMA and return shipping label.
  • There are no returns on the Pentair Colorsync 618031
  • No returns on pool cleaners.
  • No returns on opened seals and o-rings.
  • No returns on capacitors.
  • If a light is returned because it "doesn't work" and it tests fine, the cost to ship and a re-stocking fee will be deducted from the refund.
  • All products denied upon arrival at customers house WILL be charged the cost to ship.
  • Visa Gift Card Promotions: Gift cards are sent within 14 days of the order. When accepting the Visa Gift card, you agree that if your order is returned or refunded, this amount will be deducted from the refunded amount. All Visa Gift cards are sent via email in an E-Gift Card format and are non refundable.