Part # FDXLIGN1930 — the replacement igniter assembly for Hayward Universal H-Series Low NOx pool and spa heaters. This component restores reliable ignition and burner startup when the original igniter has failed or become defective.
Used when a Hayward low NOx heater fails to ignite, misfires, or the existing igniter becomes worn, corroded or damaged. Suitable for heater maintenance, refurbishment, or repair to restore full functionality.
Before servicing, shut off gas supply and power to the heater, and allow it to cool completely. Remove the heater cover and locate the existing igniter module. Disconnect wiring and mounting hardware. Install the new FDXLIGN1930 igniter assembly, reconnect wiring, re-secure mounting, restore gas and power, and perform a test ignition cycle. Confirm stable ignition and proper operation before closing the heater housing.
The FDXLIGN1930 provides genuine manufacturer replacement quality and ensures proper combustion performance and safety. Replacing a failing igniter helps restore heater reliability, extend service life and reduce recurring ignition failures.