Raypak 014941 P-R406A-EN-X #51 Digital Natural Gas Heater 360K BTU
The Raypak 014941 P-R406A-EN-X #51 Digital Natural Gas Pool and Spa Heater is a 406A-series residential heater designed for natural gas applications at 0 to 2,000 ft elevation where specified. This model features digital electronic ignition, polymer headers, a cupro-nickel heat exchanger, and a ProTek Shield™ module for added corrosion protection in demanding pool and spa environments.
This heater is commonly used on residential pools and spas where a 406A natural gas heater with digital controls, cupro-nickel tubing, and standard-elevation #51 configuration is required. Always confirm gas type, altitude, local code requirements, pool size, plumbing, venting, and heater sizing before ordering.
Product Features
- Genuine Raypak Digital pool and spa heater
- Manufacturer part number: 014941
- Model: P-R406A-EN-X #51
- 406A digital natural gas heater
- 360K BTU class cupro-nickel model
- #51 configuration for 0 to 2,000 ft elevation where specified
- Electronic ignition for reliable startup
- Digital control with LCD temperature display and diagnostic information
- Cupro-nickel heat exchanger for improved resistance in harsh water conditions
- ProTek Shield™ module included where specified
- Polymer headers for corrosion-resistant water connections
- Designed for 120/240VAC single-phase electrical service where specified
Product Details
| Brand | Raypak |
| Part Number | 014941 |
| Model | P-R406A-EN-X #51 |
| Product Type | Digital Gas Pool and Spa Heater |
| Fuel Type | Natural Gas |
| Heater Size | 406A / 360K BTU class |
| Elevation Range | 0 to 2,000 ft where specified |
| Ignition Type | Electronic Ignition |
| Control Type | Digital Control |
| Header Type | Polymer Headers |
| Heat Exchanger | Cupro-Nickel Tubing |
| Protection Module | ProTek Shield™ Module |
| Voltage | 120/240VAC where specified |
| Shipping Weight | 260 lbs |
| Application | Residential pool and spa heating |
Compatibility
- Residential pool and spa systems requiring a Raypak P-R406A-EN-X #51 natural gas heater
- Installations located at 0 to 2,000 ft elevation where this model is specified
- Applications requiring a 406A Digital Raypak heater with cupro-nickel tubing
- Outdoor pool equipment installations where this model is approved by local code
- Systems where the gas supply, electrical supply, water flow, plumbing, venting, and clearances meet Raypak installation requirements
Common Uses
- Heating residential swimming pools
- Heating attached spas when properly plumbed and controlled
- Replacing a compatible Raypak 406A natural gas cupro-nickel heater
- Pool systems where cupro-nickel tubing is preferred for added corrosion resistance
- New equipment pad installations where a 406A natural gas heater is properly sized
Important Notes
- This item is the heater only.
- Gas line, electrical wiring, bonding, venting, unions, plumbing fittings, automation wiring, check valves, bypass plumbing, pressure relief valve where required, and installation materials are sold separately unless otherwise stated.
- Verify natural gas availability, gas line sizing, and elevation range before ordering.
- This model is not a propane heater. Do not attempt to use propane unless the exact propane model is ordered.
- This is the #51 cupro-nickel natural gas configuration and is not the same as copper exchanger, propane, ASME, Low NOx, or commercial versions.
- Although cupro-nickel provides improved resistance in challenging water conditions, proper water chemistry is still required.
- Some jurisdictions require Low NOx heaters or have restrictions on standard atmospheric gas heaters. Confirm local requirements before purchase or installation.
- Improper water chemistry, low flow, scale, corrosive water, freeze damage, or improper bypass settings can damage the heater and heat exchanger.
- Gas heater installation and service should be performed by a qualified pool heater professional according to Raypak instructions and local code.
Installation Notes
- Confirm the model, fuel type, altitude range, BTU size, and local code requirements before installation.
- Install the heater on a level, non-combustible equipment pad with proper service access and clearances.
- Size the natural gas line according to the heater demand, run length, and local code.
- Confirm proper water flow through the heater before firing.
- Use proper plumbing practices and install any required check valves to protect the heater from chemical backflow.
- Bond and wire the heater according to the installation manual and applicable electrical code.
- Verify inlet/outlet plumbing orientation before startup.
- Check for gas leaks, water leaks, proper ignition, and correct temperature operation during startup.
- Register the heater and keep installation records, serial number, and startup documentation for warranty and service reference.
Related Products
- Raypak 014941 P-R406A-EN-X #51 Digital Natural Gas Heater
- Raypak 014938 P-R206A-EN-X #51 Digital Natural Gas Heater
- Raypak 014939 P-R266A-EN-X #51 Digital Natural Gas Heater
- Raypak 014940 P-R336A-EN-X #51 Digital Natural Gas Heater
- Raypak 017960F ProTek Shield Assembly, 399K BTU
- Raypak 006723F 2" CPVC Connector & Nut Kit
- Raypak 006737F 1.75 PSI Pressure Switch
- Raypak 006736F 120/240V to 24V Transformer
Maintenance Tips
- Maintain proper pool water chemistry to help protect the cupro-nickel heat exchanger.
- Keep pH, alkalinity, calcium hardness, and sanitizer within recommended ranges.
- Clean the pool filter regularly to maintain proper heater flow.
- Inspect the heater area for leaves, debris, rodents, insects, and restricted airflow.
- Check the equipment pad for water leaks, gas odor, rust, or signs of overheating.
- Winterize the heater properly in freeze-prone conditions.
- Have ignition, gas pressure, flame quality, venting, safety controls, ProTek Shield condition, and heat exchanger condition checked by a qualified heater technician during routine service.
Hours Of Operation:
Monday - Friday: 7:00 am to 5:00 pm Phoenix Time
Saturday: 8:00 am to 2:00 pm
Sunday: Closed
- We do not ship on Saturday or Sunday.
- Orders totaling more than $300 will require signature confirmation upon delivery.
- We process and prepare orders for shipment within 1 business day. Please note that many other pool supply retailers require 3–5 days of handling time before shipping.
- Orders placed after 1:00 pm Phoenix Time may not be eligible for same-day shipment.
- Expedited shipping options are available at checkout.
Return Policy:
- Products that are received damaged will receive a refund in store credit.
- Most products are eligible for return within 30 days of receipt, except where noted below.
- To initiate a return, please complete an RMA form prior to sending your item back.
- Original shipping costs are non-refundable and will be deducted from the return credit.
- Items returned missing accessories or original packaging, or that are not in the same condition as received, may be subject to a restocking fee of up to 100% depending on the condition of the item upon return.
- Some returns will be charged an automatic 15% restocking fee.
- We are unable to issue refunds for items that have been damaged or rendered inoperable due to installer error.
- Please complete the return form to receive your RMA number and return shipping label.
- Chemical products are not eligible for return under any circumstances.
- The Pentair Colorsync 618031 is not eligible for return.
- Pool cleaners are not eligible for return.
- Opened seals and o-rings are not eligible for return.
- Capacitors are not eligible for return.
- Plastic popup tools are not eligible for return.
- Automation components and circuit boards are not eligible for return.
- If a light is returned due to a reported malfunction and is found to be fully operational upon testing, return shipping costs and a restocking fee will be deducted from the refund.
- Orders refused at the time of delivery will be subject to the original shipping costs being deducted from the refund.