Call For Best Price 1-888-484-0864

Raypak 106/156 Thermal Cut-Off Fuse Kit | 005899F

Raypak SKU: 005899F
Raypak 106/156 Thermal Cut - Off Fuse Kit | 005899F - Heater Parts - img - 1

Raypak 106/156 Thermal Cut-Off Fuse Kit | 005899F

Raypak SKU: 005899F
  • In stock, ready to ship
  • Inventory on the way
$39.99 Regular price $49.99
Instant Savings: $10Sale price $39.99
/
🚚 Shipping notice loading...
Questions about returns? View our return policy.
Free US Shipping - Shipping Policy

Raypak 005899F Thermal Cut-Off Fuse / Fusible Link (Rollout Safety) – Replacement Kit

The Raypak 005899F is a safety thermal cut-off fuse (fusible link) used on select Raypak pool and spa heaters. It is designed to open the safety circuit permanently if excessive heat conditions occur in the burner/firebox area, helping protect the heater from damage caused by abnormal combustion or flame rollout conditions.

Key Details

  • Part Number: 005899F
  • Type: Thermal cut-off fuse / fusible link (non-reset)
  • Function: Safety shutoff in the rollout/overheat safety circuit
  • Common rating listed: 152°C (varies by manufacturing run; verify your existing part markings)
  • Typical electrical rating listed: 15A, 250V (verify your existing part markings)

Common Compatible Heater Families

  • Commonly listed on select Raypak heater series such as 106A / 156A / 206A / 266A / 336A / 406A (verify by your heater model/serial and parts diagram)
  • May also appear on additional Raypak P-R series variants depending on revision (confirm fitment before ordering)

When to Replace

  • Heater will not fire and troubleshooting indicates an open thermal fuse/fusible link
  • Visible heat damage, discoloration, or brittle/cracked fuse body
  • Safety circuit opens after a heat/combustion event and the fuse will not reset

Important Safety Notes

  • Do not bypass a thermal cut-off fuse. If it opened, the heater likely experienced an unsafe condition that must be corrected.
  • If the new fuse opens again, stop operation and inspect for root causes such as restricted airflow/venting, blocked burners, debris, improper gas pressure, or combustion issues.

Installation Notes

  • Shut off power and gas to the heater before service, and allow the unit to cool completely.
  • Replace the fuse in the same location and orientation as the original, using the proper mounting hardware and secure electrical connections.
  • After replacement, verify normal ignition and stable flame characteristics before leaving the heater in service.

Related Products

Installation & Maintenance Tips

  • Keep the heater cabinet and combustion air openings clear of leaves, dust, and insects to reduce overheating and rollout risk.
  • Inspect venting (where applicable) for obstruction and proper termination clearances.
  • Maintain proper water flow and clean filtration—overheating and short-cycling can contribute to repeated safety events.
  • If you have repeated nuisance shutdowns, check gas pressure, burner cleanliness, and combustion setup before replacing additional parts.
Questions about returns? View our return policy.

Hours Of Operation:

Monday - Friday: 7:00 am to 5:00 pm Phoenix Time

Saturday: 8:00 am to 2:00 pm

Sunday: Closed

  • We do not ship on Saturday or Sunday.
  • Orders totaling more than $300 will require signature confirmation upon delivery.
  • We process and prepare orders for shipment within 1 business day. Please note that many other pool supply retailers require 3–5 days of handling time before shipping.
  • Orders placed after 1:00 pm Phoenix Time may not be eligible for same-day shipment.
  • Expedited shipping options are available at checkout.

Return Policy:

  • Products that are received damaged will receive a refund in store credit.
  • Most products are eligible for return within 30 days of receipt, except where noted below.
  • To initiate a return, please complete an RMA form prior to sending your item back.
  • Original shipping costs are non-refundable and will be deducted from the return credit.
  • Items returned missing accessories or original packaging, or that are not in the same condition as received, may be subject to a restocking fee of up to 100% depending on the condition of the item upon return.
  • Some returns will be charged an automatic 15% restocking fee.
  • We are unable to issue refunds for items that have been damaged or rendered inoperable due to installer error.
  • Please complete the return form to receive your RMA number and return shipping label.
  • Chemical products are not eligible for return under any circumstances.
  • The Pentair Colorsync 618031 is not eligible for return.
  • Pool cleaners are not eligible for return.
  • Opened seals and o-rings are not eligible for return.
  • Capacitors are not eligible for return.
  • Plastic popup tools are not eligible for return.
  • Automation components and circuit boards are not eligible for return.
  • If a light is returned due to a reported malfunction and is found to be fully operational upon testing, return shipping costs and a restocking fee will be deducted from the refund.
  • Orders refused at the time of delivery will be subject to the original shipping costs being deducted from the refund.