Pentair 190059Z Rear-Mount Pressure Gauge with Clean/Dirty Indicator (0–60 PSI)

The Pentair 190059Z is an OEM rear-mount pressure gauge used on many Pentair and Sta-Rite pool filter systems and select Hi-Flow multiport valves. It features an easy-to-read 0–60 PSI scale and a clean/dirty indicator ring so you can quickly mark your “clean starting pressure” and know when it’s time to backwash or clean the filter.

Key Features

  • Range: 0–60 PSI
  • Mount: Rear/back mount (threads on the back of the gauge)
  • Indicator: Adjustable “clean/dirty” marker ring to set your baseline pressure
  • Use: Monitors filter/valve operating pressure to help schedule cleaning and diagnose flow restrictions

Common Compatibility (Verify by Model / Parts Diagram)

  • Pentair Sand Dollar sand filters
  • Pentair Tagelus sand filters
  • Pentair Triton II sand filters
  • Pentair Meteor sand filters (including select top-mount configurations)
  • Pentair FNS / FNS Plus D.E. filters
  • Pentair Nautilus / Nautilus Plus D.E. filters
  • Pentair / Sta-Rite SM & SMBW 2000/4000 series filters (select models)
  • Pentair Star / Star Polymeric filters (select models)
  • Sta-Rite Cristal-Flo II high-rate sand filters (select models)
  • Select Hi-Flow multiport valves that use a rear-mount gauge port

Pressure gauge ports can vary by generation and valve/filter body. Confirm the gauge style (rear mount) and thread type on your existing gauge and parts diagram before ordering.

How to Use the Indicator Ring

  • After cleaning/backwashing, run the system and note the stable reading.
  • Rotate the indicator ring to mark that reading as your clean baseline.
  • Clean/backwash again when pressure rises about 8–10 PSI above your baseline (or per your equipment manual).

Installation Notes

  • Shut off the pump and relieve all pressure before removing the old gauge.
  • Inspect the gauge port and sealing surface; clean away debris/scale.
  • Use an appropriate thread sealant for pool equipment (avoid over-applying so it doesn’t enter the plumbing path).
  • Tighten snugly—do not over-tighten, which can crack plastic ports.
  • Verify there are no leaks after restart and that the needle moves smoothly with pump operation.

Troubleshooting Tips

  • Reads 0 all the time: Gauge may be clogged, failed, or installed in a blocked port.
  • Needle jumps/shakes: Air in the system, pump cavitation, or a failing gauge mechanism.
  • High pressure: Dirty filter, closed/partially closed valves, return restriction, or clogged plumbing.
  • Low pressure: Suction-side air leak, clogged pump basket/impeller, or pump performance issue.

Related Products (Aqua Pool Supply)

Maintenance Tips

  • Record your clean starting pressure each season—pressure trends can reveal developing restrictions.
  • If the gauge face fogs, sticks, or reads inconsistently, replace it to avoid misleading service decisions.
  • Always bleed air from the filter after service to stabilize pressure readings.
  • Protect equipment from freezing—ice expansion can crack ports and damage gauges.
Questions about returns? View our return policy.

Hours Of Operation: 

Monday - Friday: 8:00 am to 4:00 pm Phoenix Time

Saturday and Sunday: Closed

  • Orders costing more than  $300 WILL be required to have signature confirmation upon delivery.
  • Handling time is typically only 1 day.   
  • Any item ordered after 1pm Phoenix time, may not ship same-day.
  • Call us if you require expedited shipping and we can give you quotes based on your needs.

Return Policy:

  • All products, except as noted below, are eligible for return up to 30 days after receipt of item.
  • For returns, an RMA form must be filled out HERE or customers can call for additional help.
  • Shipping costs will be deducted from all returned items.
  • Any item that is missing accessories, original packaging, or is not returned in the same condition that it was received in, may be subject to a re-stocking fee up to 100% based on the condition we receive it in. 
  • Items broken, damaged, or inoperable due to installer error will not be refunded.
  • Fill out the return form or give us a call to obtain an RMA and return shipping label.
  • There are no returns on the Pentair Colorsync 618031
  • No returns on pool cleaners.
  • No returns on opened seals and o-rings.
  • No returns on capacitors.
  • If a light is returned because it "doesn't work" and it tests fine, the cost to ship and a re-stocking fee will be deducted from the refund.
  • All products denied upon arrival at customers house WILL be charged the cost to ship.
  • Visa Gift Card Promotions: Gift cards are sent within 14 days of the order. When accepting the Visa Gift card, you agree that if your order is returned or refunded, this amount will be deducted from the refunded amount. All Visa Gift cards are sent via email in an E-Gift Card format and are non refundable.