Georg Fischer 360002213 2" Socket Fusion Tee

The Georg Fischer 360002213 Socket Fusion Tee is a 2" IPS polyethylene fusion fitting used to create a branch connection in compatible socket-fusion piping systems. This tee is commonly used in qualified gas, utility, and specialty piping applications where Georg Fischer / GF Central Plastics socket-fusion fittings are specified.

This fitting is designed for socket-fusion installation and is not a standard PVC slip tee. Always verify pipe material, pipe size, DR rating, code requirements, and approved fusion procedure before installation.

Product Features

  • Genuine Georg Fischer / GF Central Plastics socket-fusion tee
  • Manufacturer part number: 360002213
  • 2" IPS tee fitting
  • Socket-fusion connection style
  • Used to create a branch connection in compatible fusion piping systems
  • Commonly listed for PE2708 / polyethylene piping applications where specified
  • IAPMO and CSA approved where listed by the manufacturer or distributor
  • Suitable for approved socket-fusion methods when installed by a qualified installer

Product Details

Brand Georg Fischer / GF Central Plastics
Part Number 360002213
Product Type Socket Fusion Tee
Nominal Size 2" IPS
Connection Type Socket Fusion
Material Type Polyethylene / PE fusion fitting where specified
Common DR Reference DR11 where listed in Georg Fischer socket-fusion fitting references
Application Approved gas, utility, and specialty fusion piping systems

Common Uses

  • Creating a 2" branch line in compatible socket-fusion piping
  • Approved polyethylene gas piping systems
  • Utility and specialty piping installations requiring GF socket-fusion fittings
  • Replacement applications where the existing fitting or specification calls for Georg Fischer 360002213
  • Equipment pad or heater gas-line work only where local code and approved materials allow this fitting

Compatibility

  • Compatible 2" IPS polyethylene pipe where socket-fusion fittings are specified
  • Georg Fischer / GF Central Plastics socket-fusion systems requiring part number 360002213
  • Approved PE2708 / polyethylene socket-fusion applications where listed by the project specification
  • Installations requiring a 2" x 2" x 2" socket-fusion tee with matching pipe, tooling, and approved procedure

Important Notes

  • This item is the socket-fusion tee fitting only.
  • Pipe, socket-fusion machine, heater faces, chamfer tools, cold rings, depth gauges, transition fittings, valves, couplings, and installation tools are sold separately unless otherwise stated.
  • This is not a PVC Schedule 40 slip tee and is not installed with PVC primer or solvent cement.
  • Socket-fusion fittings require proper fusion tooling, preparation, heating time, joining depth, cooling time, and installer qualification.
  • Verify the pipe material, IPS size, DR rating, fuel gas approval, local code requirements, and project specifications before ordering or installing.
  • Do not use this fitting for compressed air, non-approved fluids, or any application outside the manufacturer’s listed specifications.
  • Gas piping work should be performed by a licensed or qualified professional according to local code.

Installation Notes

  • Confirm the fitting part number and pipe specification before installation.
  • Use only approved socket-fusion equipment and tooling for the pipe size and material.
  • Cut pipe square and clean all joining surfaces before fusion.
  • Use the correct chamfer gauge, depth gauge, cold ring, heater face, and fusion temperature for the approved procedure.
  • Do not overheat, underheat, twist, or disturb the joint during cooling.
  • Allow the fused joint to cool completely before pressure testing or placing the system in service.
  • Pressure test and inspect the installation according to applicable code and project requirements.
  • Replace the fitting if it is gouged, contaminated, overheated, deformed, or improperly fused.

Related Products

Maintenance Tips

  • Inspect fusion joints during service for movement, impact damage, stress, or visible deformation.
  • Protect exposed piping and fittings from physical damage.
  • Do not modify, heat, or rework a completed fusion joint after it has cooled.
  • Have gas or utility piping inspected by a qualified professional if leaks, odors, pressure loss, or damage are suspected.
  • Keep installation records, part numbers, and pressure-test documentation for future service reference.
Questions about returns? View our return policy.

Hours Of Operation:

Monday - Friday: 7:00 am to 5:00 pm Phoenix Time

Saturday: 8:00 am to 2:00 pm

Sunday: Closed

  • We do not ship on Saturday or Sunday.
  • Orders totaling more than $300 will require signature confirmation upon delivery.
  • We process and prepare orders for shipment within 1 business day. Please note that many other pool supply retailers require 3–5 days of handling time before shipping.
  • Orders placed after 1:00 pm Phoenix Time may not be eligible for same-day shipment.
  • Expedited shipping options are available at checkout.

Return Policy:

  • Products that are received damaged will receive a refund in store credit.
  • Most products are eligible for return within 30 days of receipt, except where noted below.
  • To initiate a return, please complete an RMA form prior to sending your item back.
  • Original shipping costs are non-refundable and will be deducted from the return credit.
  • Items returned missing accessories or original packaging, or that are not in the same condition as received, may be subject to a restocking fee of up to 100% depending on the condition of the item upon return.
  • Some returns will be charged an automatic 15% restocking fee.
  • We are unable to issue refunds for items that have been damaged or rendered inoperable due to installer error.
  • Please complete the return form to receive your RMA number and return shipping label.
  • Chemical products are not eligible for return under any circumstances.
  • The Pentair Colorsync 618031 is not eligible for return.
  • Pool cleaners are not eligible for return.
  • Opened seals and o-rings are not eligible for return.
  • Capacitors are not eligible for return.
  • Plastic popup tools are not eligible for return.
  • Automation components and circuit boards are not eligible for return.
  • If a light is returned due to a reported malfunction and is found to be fully operational upon testing, return shipping costs and a restocking fee will be deducted from the refund.
  • Orders refused at the time of delivery will be subject to the original shipping costs being deducted from the refund.