Stenner AK600 Flow Indicator with Bracket – 1/4" Discharge Line

The Stenner AK600 is a compact, in-line flow indicator for 1/4" tubing that provides a quick visual check that your Stenner pump is actually moving solution through the discharge line. It installs in-line and uses a clear viewing body with an internal indicator (ball-style) so you can confirm flow without disconnecting tubing or fittings.

Key Features

  • Visual confirmation of flow: Helps verify chemical is being pumped through the discharge line at a glance
  • 1/4" tubing size: Designed for systems using 1/4" Stenner discharge tubing/connections
  • In-line installation: Mounts directly in the discharge line to show movement during pump operation
  • Includes bracket: Bracket helps secure the indicator for easier viewing and a cleaner install
  • Helps troubleshooting: Useful for diagnosing loss of prime, suction leaks, clogged injection points, or worn pump tubes

Typical Compatibility

  • Commonly used with Stenner pump setups that utilize 1/4" discharge connections
  • Frequently referenced for Stenner 45, 85, 100, and 170 Series (adjustable & fixed), plus related feed systems using 1/4" lines
  • Important: Confirm your tubing size (1/4") and connection style before ordering

Specifications

  • Part Number: AK600
  • Line Size: 1/4"
  • Application: Chemical feed / dosing pump discharge line
  • Pressure Rating: Commonly rated up to 100 PSI (verify against your system requirements)

Installation Notes

  • Install in the discharge line where it’s easy to see during normal operation.
  • Follow any flow direction markings on the indicator body (if present).
  • Use proper tubing cuts (square, clean) and fully seat tubing/fittings to prevent suction/pressure leaks.
  • Secure using the included bracket so the indicator stays oriented for clear viewing.

Related Products

Installation & Maintenance Tips

  • If the indicator shows no movement, check for loss of prime, an empty tank, a cracked suction line, or a clogged foot valve/strainer.
  • Confirm the pump tube condition; a flattened, stiff, or cracked tube often reduces output and may prevent visible flow.
  • Inspect the injection point for scale or debris—plugged injection fittings commonly stop flow on otherwise working systems.
  • Rinse the indicator exterior after chemical splashes and keep it out of direct UV when possible to extend clarity and component life.
  • Periodically check connections for drips or air intrusion; even small leaks can cause inconsistent feed rates.
Questions about returns? View our return policy.

Hours Of Operation:

Monday - Friday: 7:00 am to 5:00 pm Phoenix Time

Saturday: 8:00 am to 2:00 pm

Sunday: Closed

  • We do not ship on Saturday or Sunday.
  • Orders totaling more than $300 will require signature confirmation upon delivery.
  • We process and prepare orders for shipment within 1 business day. Please note that many other pool supply retailers require 3–5 days of handling time before shipping.
  • Orders placed after 1:00 pm Phoenix Time may not be eligible for same-day shipment.
  • Expedited shipping options are available at checkout.

Return Policy:

  • Products that are received damaged will receive a refund in store credit.
  • Most products are eligible for return within 30 days of receipt, except where noted below.
  • To initiate a return, please complete an RMA form prior to sending your item back.
  • Original shipping costs are non-refundable and will be deducted from the return credit.
  • Items returned missing accessories or original packaging, or that are not in the same condition as received, may be subject to a restocking fee of up to 100% depending on the condition of the item upon return.
  • Some returns will be charged an automatic 15% restocking fee.
  • We are unable to issue refunds for items that have been damaged or rendered inoperable due to installer error.
  • Please complete the return form to receive your RMA number and return shipping label.
  • Chemical products are not eligible for return under any circumstances.
  • The Pentair Colorsync 618031 is not eligible for return.
  • Pool cleaners are not eligible for return.
  • Opened seals and o-rings are not eligible for return.
  • Capacitors are not eligible for return.
  • Plastic popup tools are not eligible for return.
  • Automation components and circuit boards are not eligible for return.
  • If a light is returned due to a reported malfunction and is found to be fully operational upon testing, return shipping costs and a restocking fee will be deducted from the refund.
  • Orders refused at the time of delivery will be subject to the original shipping costs being deducted from the refund.