Call For Best Price 1-888-484-0864

Praher 1-1/2" MIP x SKT High Temp Pump Union w/ O-Ring | 150-906

Praher SKU: 150-906
Praher 1 - 1/2" MIP x SKT High Temp Pump Union w/ O - Ring | 150 - 906 - Pump Parts - img - 1

Praher 1-1/2" MIP x SKT High Temp Pump Union w/ O-Ring | 150-906

Praher SKU: 150-906
  • In stock, ready to ship
  • Inventory on the way
$14.99 Regular price $19.99
Instant Savings: $5Sale price $14.99
/
🚚 Shipping notice loading...
Questions about returns? View our return policy.
Free US Shipping - Shipping Policy

Praher 150-906 High Temp Union – 1½″ MIP × 1½″ Slip

The Praher 150-906 is a durable, high-temperature union adaptor designed for pool and spa plumbing applications. With a 1½″ male iron pipe (MIP) thread on one end and a 1½″ slip socket on the other, it allows for convenient service access while handling elevated temperatures.

Key Features

  • 1½″ MIP x 1½″ slip connection—ideal for matching common pump and filter ports.
  • High-temperature-rated polymer body supports working temperatures up to approx. 176 °F (80 °C).
  • Includes O-ring seal for secure, tool-free connection and service access.
  • Service-friendly design—allows for quick removal without disturbing glued-in plumbing.

Technical Specifications

  • Part Number: 150-906
  • Connections: 1½″ male iron pipe (threaded) × 1½″ slip socket
  • Max Working Temp: Approx. 176 °F (80 °C)
  • Max Working Pressure: Approx. 50 psi (3.5 bar)
  • Application: Pool/spa pump or filter plumbing union for installations requiring workflow access and high-temp operation

Installation & Compatibility Notes

Prior to installation, shut off pump power and relieve system pressure. Cut or remove existing plumbing to achieve clean pipe ends. Solvent-cement the slip end according to your plumbing code and thread the MIP end into the matching female port on the equipment body. Ensure the O-ring is lubricated and seated fully before tightening by hand. After installation, restore circulation and inspect for leaks or air intrusion.

Maintenance Tips

  • Inspect the union O-ring annually for wear, cracking or flattening—replace if any signs of degradation appear.
  • Check the union body and faces when servicing equipment for scratches or gouges that may compromise the seal.
  • Keep a replacement O-ring and union body in your parts kit—unions are commonly serviced when pumps, filters or heaters are removed for seasonal maintenance.

Why Choose This Union?

The Praher 150-906 offers a reliable solution for high-temperature pool and spa plumbing systems that require both a secure seal and service-friendly access. Its combination of threaded and slip connections makes it versatile for retrofits or new installations, and its material rating supports operations around equipment subject to elevated heat. For pool professionals, stocking this part means faster service calls and fewer plumbing disruptions.

Questions about returns? View our return policy.

Hours Of Operation:

Monday - Friday: 7:00 am to 5:00 pm Phoenix Time

Saturday: 8:00 am to 2:00 pm

Sunday: Closed

  • We do not ship on Saturday or Sunday.
  • Orders totaling more than $300 will require signature confirmation upon delivery.
  • We process and prepare orders for shipment within 1 business day. Please note that many other pool supply retailers require 3–5 days of handling time before shipping.
  • Orders placed after 1:00 pm Phoenix Time may not be eligible for same-day shipment.
  • Expedited shipping options are available at checkout.

Return Policy:

  • Products that are received damaged will receive a refund in store credit.
  • Most products are eligible for return within 30 days of receipt, except where noted below.
  • To initiate a return, please complete an RMA form prior to sending your item back.
  • Original shipping costs are non-refundable and will be deducted from the return credit.
  • Items returned missing accessories or original packaging, or that are not in the same condition as received, may be subject to a restocking fee of up to 100% depending on the condition of the item upon return.
  • Some returns will be charged an automatic 15% restocking fee.
  • We are unable to issue refunds for items that have been damaged or rendered inoperable due to installer error.
  • Please complete the return form to receive your RMA number and return shipping label.
  • Chemical products are not eligible for return under any circumstances.
  • The Pentair Colorsync 618031 is not eligible for return.
  • Pool cleaners are not eligible for return.
  • Opened seals and o-rings are not eligible for return.
  • Capacitors are not eligible for return.
  • Plastic popup tools are not eligible for return.
  • Automation components and circuit boards are not eligible for return.
  • If a light is returned due to a reported malfunction and is found to be fully operational upon testing, return shipping costs and a restocking fee will be deducted from the refund.
  • Orders refused at the time of delivery will be subject to the original shipping costs being deducted from the refund.