{"product_id":"safety-relief-valve-rvw40-50","title":"APOLLO SAFETY RELIEF VALVE RVW40-50","description":"\u003cdiv\u003e\n  \u003ch2\u003eApollo RVW40-50 3\/4\" Bronze Safety Relief Valve - 50 PSI\u003c\/h2\u003e\n\n  \u003cp\u003eThe Apollo RVW40-50 Safety Relief Valve is a bronze 3\/4\" hot water relief valve designed to help protect compatible pool heaters, boilers, and hot water systems from excessive pressure. This valve is factory set at 50 PSI and features a 3\/4\" MNPT inlet with a 3\/4\" FNPT outlet.\u003c\/p\u003e\n\n  \u003cp\u003eThis replacement safety relief valve is commonly used when the existing valve is leaking, corroded, stuck, damaged, or no longer operating properly. A properly functioning relief valve is an important safety component that helps relieve excess system pressure when required.\u003c\/p\u003e\n\n  \u003ch3\u003eProduct Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eApollo RVW40 series safety relief valve\u003c\/li\u003e\n    \u003cli\u003ePart number: RVW40-50\u003c\/li\u003e\n    \u003cli\u003e50 PSI pressure setting\u003c\/li\u003e\n    \u003cli\u003e3\/4\" MNPT inlet x 3\/4\" FNPT outlet\u003c\/li\u003e\n    \u003cli\u003eBronze body construction\u003c\/li\u003e\n    \u003cli\u003e697,000 BTU\/hr capacity\u003c\/li\u003e\n    \u003cli\u003eMaximum temperature rating of 250°F\u003c\/li\u003e\n    \u003cli\u003eDesigned for hot water heating systems, pool heater applications, boilers, and similar equipment\u003c\/li\u003e\n    \u003cli\u003eHelps protect equipment from excessive pressure\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eProduct Details\u003c\/h3\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eApollo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eRVW40\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eRVW40-50\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eSafety Relief Valve\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003ePressure Setting\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e50 PSI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eConnection Size\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e3\/4\"\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eMNPT Inlet x FNPT Outlet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eBronze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e697,000 BTU\/hr\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e250°F\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003ePool heater, boiler, and hot water system pressure relief\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch3\u003eCommon Uses\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eReplacing a leaking pool heater relief valve\u003c\/li\u003e\n    \u003cli\u003eReplacing a worn or corroded hot water safety relief valve\u003c\/li\u003e\n    \u003cli\u003ePressure protection on compatible pool heaters and hot water systems\u003c\/li\u003e\n    \u003cli\u003eService replacement during heater or boiler maintenance\u003c\/li\u003e\n    \u003cli\u003eCorrecting leaks from a relief valve discharge outlet\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eImportant Notes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eVerify the required pressure rating before ordering.\u003c\/li\u003e\n    \u003cli\u003eThis valve is set at 50 PSI and should only be used where a 50 PSI relief valve is specified.\u003c\/li\u003e\n    \u003cli\u003eVerify inlet size, outlet size, thread type, and equipment requirements before installation.\u003c\/li\u003e\n    \u003cli\u003eThis item is the safety relief valve only.\u003c\/li\u003e\n    \u003cli\u003eDischarge piping, adapters, thread sealant, and other plumbing parts are sold separately unless otherwise stated.\u003c\/li\u003e\n    \u003cli\u003eA leaking relief valve may indicate high system pressure, thermal expansion, debris in the valve seat, or a failed valve.\u003c\/li\u003e\n    \u003cli\u003eNever plug, cap, block, or disable a safety relief valve.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eTurn off all equipment before servicing the valve.\u003c\/li\u003e\n    \u003cli\u003eAllow heater or hot water equipment to cool before removal.\u003c\/li\u003e\n    \u003cli\u003eRelieve system pressure before removing the old valve.\u003c\/li\u003e\n    \u003cli\u003eUse proper thread sealant suitable for the application.\u003c\/li\u003e\n    \u003cli\u003eInstall the valve in the correct orientation according to equipment and valve manufacturer instructions.\u003c\/li\u003e\n    \u003cli\u003eRoute discharge piping safely according to local code and manufacturer requirements.\u003c\/li\u003e\n    \u003cli\u003eDo not reduce, plug, or restrict the discharge outlet.\u003c\/li\u003e\n    \u003cli\u003eInstallation should be completed by a qualified pool heater technician, plumber, or licensed professional.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eRelated Products\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/pentair-air-relief-valve-and-gauge-kit-for-system-3%C2%AE-filters-24850-0105\"\u003ePentair 24850-0105 Air Relief Valve and Gauge Kit for System 3 Filters\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/hayward-vertical-grid-de-filters-air-relief-valve-dex2400s\"\u003eHayward DEX2400S Air Relief Valve for Vertical Grid D.E. Filters\u003c\/a\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eMaintenance Tips\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eInspect the relief valve periodically for leaks, corrosion, mineral buildup, or damage.\u003c\/li\u003e\n    \u003cli\u003eReplace the valve if it drips continuously, fails to reseat, or shows signs of corrosion.\u003c\/li\u003e\n    \u003cli\u003eKeep the discharge outlet clear and unobstructed.\u003c\/li\u003e\n    \u003cli\u003eMaintain proper pool water chemistry to help reduce scale buildup and corrosion.\u003c\/li\u003e\n    \u003cli\u003eIf the relief valve opens repeatedly, have the system pressure and heater operation inspected before replacing parts unnecessarily.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Apollo","offers":[{"title":"Default Title","offer_id":52836413047100,"sku":"RVW40-50","price":69.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/aquapoolsupply.com\/products\/safety-relief-valve-rvw40-50","provider":"Aqua Pool Supply","version":"1.0","type":"link"}