{"product_id":"raypak-crosswind-v-8550-heat-pump-electric-pool-heater-twph-8550eht08","title":"Raypak Crosswind V 8550 Heat Pump Electric Pool Heater TWPH-8550EHT08","description":"\u003cdiv\u003e\n  \u003ch2\u003eRaypak TWPH-8550EHT08 Crosswind V 8550 Electric Heat Pump Pool Heater 138K BTU\u003c\/h2\u003e\n\n  \u003cp\u003eThe Raypak TWPH-8550EHT08 Crosswind V® 8550 Electric Heat Pump Pool Heater is a high-capacity vertical-discharge heat pump designed for residential pool and spa heating. This standard Crosswind V model provides efficient electric heat pump performance with a compact footprint, modern cabinet design, digital controls, and service-friendly front access.\u003c\/p\u003e\n\n  \u003cp\u003eThis model is commonly used for in-ground pools and pool\/spa systems where a 208-230VAC electric heat pump is preferred over a gas heater. Always confirm pool size, electrical service, breaker size, water flow, equipment pad space, plumbing layout, local code, and heater sizing before ordering.\u003c\/p\u003e\n\n  \u003ch3\u003eProduct Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eGenuine Raypak Crosswind V® electric heat pump pool heater\u003c\/li\u003e\n    \u003cli\u003eManufacturer model \/ SKU: TWPH-8550EHT08\u003c\/li\u003e\n    \u003cli\u003eCrosswind V 8550 standard heat pump model\u003c\/li\u003e\n    \u003cli\u003e138,000 BTU\/h class heating performance where specified\u003c\/li\u003e\n    \u003cli\u003eVertical discharge design with a smaller equipment pad footprint\u003c\/li\u003e\n    \u003cli\u003e208-230VAC, single-phase electrical service where specified\u003c\/li\u003e\n    \u003cli\u003eDigital control with microprocessor\u003c\/li\u003e\n    \u003cli\u003eDigital diagnostics for service and operation feedback\u003c\/li\u003e\n    \u003cli\u003eTitanium heat exchanger for pool and spa water applications\u003c\/li\u003e\n    \u003cli\u003eStandard 2\" PVC water connections\u003c\/li\u003e\n    \u003cli\u003eIntegrated Wi-Fi and Raymote™ fleet monitoring capability where supported\u003c\/li\u003e\n    \u003cli\u003eVariable speed pump control capability where installed and configured correctly\u003c\/li\u003e\n    \u003cli\u003eDesigned for low-noise operation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eProduct Details\u003c\/h3\u003e\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eRaypak\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eTWPH-8550EHT08\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eCrosswind V®\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eElectric Heat Pump Pool and Spa Heater\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eModel Size\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e8550\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eEnergy Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eHeat Pump\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e138,000 BTU\/h class where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e6.0 where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e208-230VAC, 1 phase, 60 Hz where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eElectrical Input\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e6.6 kW where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eMinimum Amps\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e46 amps where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eRecommended Breaker\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e60 amps where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eTitanium\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eR-410A where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eWater Connections\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e2\" PVC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eMax Water Flow\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e60 GPM where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eSound Rating\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e64 dBA where specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e330 lbs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e348 lbs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eResidential pool and spa heating\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch3\u003eCompatibility\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eResidential pools and spas requiring a Raypak Crosswind V TWPH-8550EHT08 heat pump\u003c\/li\u003e\n    \u003cli\u003ePool systems with 208-230VAC single-phase electrical service available\u003c\/li\u003e\n    \u003cli\u003eEquipment pads where a vertical-discharge heat pump is preferred\u003c\/li\u003e\n    \u003cli\u003eSystems using 2\" pool plumbing where installed according to Raypak requirements\u003c\/li\u003e\n    \u003cli\u003eApplications where electric heat pump heating is preferred over natural gas or propane heating\u003c\/li\u003e\n    \u003cli\u003eInstallations where water flow, electrical service, breaker size, clearances, and local code requirements are met\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eCommon Uses\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eHeating residential swimming pools\u003c\/li\u003e\n    \u003cli\u003eHeating attached spas when properly sized and plumbed\u003c\/li\u003e\n    \u003cli\u003eReplacing a compatible Crosswind V 8550 heat pump\u003c\/li\u003e\n    \u003cli\u003eAdding efficient electric heat pump heating to an existing equipment pad\u003c\/li\u003e\n    \u003cli\u003eApplications where a vertical-discharge heat pump design helps reduce side-clearance limitations\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eImportant Notes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eThis item is the heat pump heater only.\u003c\/li\u003e\n    \u003cli\u003eElectrical wiring, disconnect, breaker, conduit, bonding, plumbing fittings, unions, check valves, bypass plumbing where required, equipment pad, automation wiring, and installation materials are sold separately unless otherwise stated.\u003c\/li\u003e\n    \u003cli\u003eThis is an electric heat pump and is not a natural gas or propane heater.\u003c\/li\u003e\n    \u003cli\u003eThis is the standard TWPH-8550EHT08 model and is not the same as the EHC heat\/cool model.\u003c\/li\u003e\n    \u003cli\u003eVerify electrical service, amperage, breaker size, wire size, local code, and utility requirements before purchase or installation.\u003c\/li\u003e\n    \u003cli\u003eHeat pump performance depends on air temperature, water temperature, humidity, wind exposure, plumbing design, flow rate, pool cover usage, and overall pool heat loss.\u003c\/li\u003e\n    \u003cli\u003ePool sizing should be confirmed by a qualified pool professional, especially for large pools, shaded pools, windy locations, attached spas, or extended-season heating.\u003c\/li\u003e\n    \u003cli\u003eImproper water chemistry, low flow, scale, freeze damage, incorrect bypass settings, or restricted airflow can damage the heat pump.\u003c\/li\u003e\n    \u003cli\u003eInstallation and service should be performed by a qualified pool heat pump professional according to Raypak instructions and local electrical code.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eConfirm model TWPH-8550EHT08, voltage, amperage, breaker size, plumbing requirements, and local code requirements before installation.\u003c\/li\u003e\n    \u003cli\u003eInstall the heat pump on a level, stable equipment pad with proper drainage and service access.\u003c\/li\u003e\n    \u003cli\u003eMaintain required airflow clearances around the cabinet and vertical discharge area.\u003c\/li\u003e\n    \u003cli\u003eUse proper 2\" plumbing practices and confirm inlet\/outlet orientation before startup.\u003c\/li\u003e\n    \u003cli\u003eConfirm proper water flow before operating the unit.\u003c\/li\u003e\n    \u003cli\u003eInstall any required bypass plumbing according to the system design and Raypak guidance.\u003c\/li\u003e\n    \u003cli\u003eBond and wire the unit according to the installation manual and applicable electrical code.\u003c\/li\u003e\n    \u003cli\u003eDo not block the air inlet or discharge area with walls, fences, plants, equipment, or covers.\u003c\/li\u003e\n    \u003cli\u003eSet up Wi-Fi and Raymote™ features only after the unit has been safely installed and commissioned.\u003c\/li\u003e\n    \u003cli\u003eCheck for water leaks, proper flow, correct voltage, and correct heating operation during startup.\u003c\/li\u003e\n    \u003cli\u003eRegister the unit and keep installation records, serial number, and startup documentation for warranty and service reference.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eRelated Products\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/raypak-crosswind-v-8550-heat-pump-electric-pool-heater-twph-8550eht08\"\u003eRaypak TWPH-8550EHT08 Crosswind V 8550 Heat Pump Electric Pool Heater\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/raypak-model-r404a-avia%C2%AE-pool-spa-heater-natural-gas-399-mbtuh-120-240v-018045\"\u003eRaypak 018045 R404A AVIA® Natural Gas Heater\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/raypakpr406aenc51digitalnaturalgasheater399kbtuelectronicignitionpolymerheaderscopperexchanger260lbs009223ray009223\"\u003eRaypak 009223 P-R406A-EN-C #51 Digital Natural Gas Heater\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/raypakpr406aepc57digitalpropanegasheater399kbtuelectronicignitionpolymerheaderscopperexchanger260lbs009227ray009227\"\u003eRaypak 009227 P-R406A-EP-C #57 Digital Propane Gas Heater\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/raypakpr406aenx51digitalnaturalgasheater360kbtucupronickelexchanger260lbsprotekshieldmodule014941ray014941\"\u003eRaypak 014941 P-R406A-EN-X #51 Digital Natural Gas Heater\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/products\/raypakpoolheaterdrainplugkit006721fray006721f\"\u003eRaypak 006721F Pool Heater Drain Plug Kit\u003c\/a\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eMaintenance Tips\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eMaintain proper pool water chemistry to help protect the titanium heat exchanger and internal components.\u003c\/li\u003e\n    \u003cli\u003eKeep pH, alkalinity, calcium hardness, and sanitizer within recommended ranges.\u003c\/li\u003e\n    \u003cli\u003eClean the pool filter regularly to maintain proper water flow through the heat pump.\u003c\/li\u003e\n    \u003cli\u003eKeep leaves, debris, landscaping, and equipment away from the air inlet and vertical discharge area.\u003c\/li\u003e\n    \u003cli\u003eInspect the equipment pad for water leaks, vibration, blocked airflow, corrosion, or electrical issues.\u003c\/li\u003e\n    \u003cli\u003eKeep Wi-Fi credentials and app access updated if using Raymote™ features.\u003c\/li\u003e\n    \u003cli\u003eWinterize the heat pump properly in freeze-prone conditions.\u003c\/li\u003e\n    \u003cli\u003eHave refrigerant circuit, electrical components, water flow, controls, and heat exchanger condition checked by a qualified heat pump technician during routine service.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":52285705945404,"sku":"TWPH-8550EHT08","price":5142.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/aquapoolsupply.com\/products\/raypak-crosswind-v-8550-heat-pump-electric-pool-heater-twph-8550eht08","provider":"Aqua Pool Supply","version":"1.0","type":"link"}