{"product_id":"haywardphprobereplacementglxprobephhppglxprobeph","title":"Hayward pH Probe Replacement | GLX-PROBE-PH","description":"\u003cdiv class=\"product-description\"\u003e\n\n  \u003ch2\u003eHayward GLX-PROBE-PH Replacement pH Probe (Open Line) — Sense \u0026amp; Dispense \/ AQL-CHEM\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The Hayward \u003cstrong\u003eGLX-PROBE-PH\u003c\/strong\u003e is a genuine OEM \u003cstrong\u003ereplacement pH probe\u003c\/strong\u003e used to measure pool water pH in compatible\n    Hayward chemistry automation systems. It restores accurate pH monitoring when your existing probe is old, drifting, slow to respond, or has failed.\n  \u003c\/p\u003e\n\n  \u003ch3\u003eFits \/ Compatibility\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eHayward \u003cstrong\u003eSense \u0026amp; Dispense\u003c\/strong\u003e chemistry systems: \u003cstrong\u003eAQL-CHEM\u003c\/strong\u003e and \u003cstrong\u003eAQL-CHEM-UPG\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eAlso commonly listed for compatible Hayward salt chlorine\/automation systems:\n      \u003cstrong\u003eAQR-PRO-SD\u003c\/strong\u003e and \u003cstrong\u003eHPC-4-ACT-RC\u003c\/strong\u003e (verify your configuration\/parts diagram)\u003c\/li\u003e\n    \u003cli\u003ePool Type: \u003cstrong\u003eIn-Ground\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eWhat It Fixes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003epH readings that \u003cstrong\u003edrift\u003c\/strong\u003e or no longer match manual testing\u003c\/li\u003e\n    \u003cli\u003eSlow response to chemical changes or unstable pH display\u003c\/li\u003e\n    \u003cli\u003eProbe that is worn out, damaged, or has a compromised cable\/connector\u003c\/li\u003e\n    \u003cli\u003eChem automation that cannot maintain stable pH due to inaccurate sensing\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eOEM Hayward replacement probe for reliable fit and signal compatibility\u003c\/li\u003e\n    \u003cli\u003eDesigned for continuous pH monitoring in automated chemistry control systems\u003c\/li\u003e\n    \u003cli\u003eDirect-replacement style installation for supported Hayward Sense \u0026amp; Dispense setups\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eWhat’s Included\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e1 \u003cstrong\u003eGLX-PROBE-PH\u003c\/strong\u003e pH probe\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eTurn off equipment power before servicing chemistry controllers.\u003c\/li\u003e\n    \u003cli\u003eInstall the probe in the correct location in the sensing cell\/sample stream as directed by your system manual.\u003c\/li\u003e\n    \u003cli\u003eAfter replacement, \u003cstrong\u003ecalibrate the pH probe\u003c\/strong\u003e using proper calibration solution(s) for accurate readings.\u003c\/li\u003e\n    \u003cli\u003eKeep the probe wet during handling; avoid letting the sensing tip dry out.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSpecs (Quick Reference)\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003ePart Number: \u003cstrong\u003eGLX-PROBE-PH\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003ePart Type: \u003cstrong\u003eSanitization Parts\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eChannel: \u003cstrong\u003eOpen Line\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eWarranty: \u003cstrong\u003e1-Year (Parts Only)\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eApprox. Shipping Weight: \u003cstrong\u003e1 lb\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eRelated Products\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/search?q=GLX-PROBE-PH\"\u003eHayward GLX-PROBE-PH pH Probe (search)\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/search?q=GLX-PROBE-ORP\"\u003eHayward GLX-PROBE-ORP ORP Probe (search)\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/search?q=HL-CHEM\"\u003eHayward HL-CHEM Sense \u0026amp; Dispense Kit (search)\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/search?q=AQL-CHEM\"\u003eHayward AQL-CHEM Parts \u0026amp; Accessories (search)\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/search?q=pH%20calibration%20solution\"\u003epH Probe Calibration Solution (search)\u003c\/a\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003ca href=\"https:\/\/aquapoolsupply.com\/search?q=pool%20chemical%20feed%20pump\"\u003eAcid Feed Pumps \/ pH Reduction Pumps (search)\u003c\/a\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr\u003e\n\n  \u003ch3\u003eMaintenance Tips\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eRinse the probe tip gently with clean water during service—do not scrub with abrasive materials.\u003c\/li\u003e\n    \u003cli\u003eCalibrate on schedule (and anytime readings drift from your reliable manual test kit).\u003c\/li\u003e\n    \u003cli\u003eMaintain balanced water chemistry to reduce scale buildup that can coat probes and affect accuracy.\u003c\/li\u003e\n    \u003cli\u003eIf your readings become unstable, check sample flow through the sensing cell and inspect for air bubbles in the line.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":52589938737468,"sku":"GLX-PROBE-PH","price":399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/3280\/9276\/files\/hayward-ph-probe-replacement-glx-probe-ph-chemical-feeder-parts-8435333.jpg?v=1772790146","url":"https:\/\/aquapoolsupply.com\/products\/haywardphprobereplacementglxprobephhppglxprobeph","provider":"Aqua Pool Supply","version":"1.0","type":"link"}